Summary for Test 2020-07-15-48-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 213746
DEA: 080Q75U4
EFIS: 0817000114
DIST-CO-RTE-PM08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Award Date04/18/2019
Closeout Date06/28/2022
Work DescriptionREPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location DescriptionNot set
QA Service Level1 (Verified on 06/17/2019)

Sample Information

Sample Taken Date07/15/2020 Sample Unique Key48
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/22/2020
Sample typeVerification A brief description of the sampleJMF 3/4" RHMA-G-SP 0.50% LAS
The quantity of what the sample constitutes4 Bags Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byVulcan Corona Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0449G-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials- Corona Drum Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0027, 91-33-0073
The fabricator's/manufacturer's product name for the sample3/4 RHMA-G-SP The fabricator/manufacturer designation for the sample
The plant number226108 CORD SJR A detailed description of where the material sample was collectedBelt Cut at Vulcan Corona Plant
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-07-15-48
DIME Test ID: 2020-07-15-48-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-07-29

Test Results


Input Type: Measured
Tester's full name: Danilo Ferrer
Date of test: 07/24/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 965.9 grams
Mass of the pycnometer with water (B): 655.1 grams
Mass of the oven dried sample (before pycnometer) (A): 491.7 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491.7 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity: 2.599
Bulk specific gravity (SSD Basis): 2.643
Apparent specific gravity: 2.718
Absorption: 1.7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/29/2020