Summary for Test 2020-07-16-2-1

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 213747
DEA: 080Q9104
EFIS: 0800020580
DIST-CO-RTE-PM08-SBD-10-R23.8
Award Date01/30/2019
Closeout Date07/27/2022
Work DescriptionRETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY.
Location DescriptionSAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES
QA Service Level1 (Verified on 03/18/2019)

Sample Information

Sample Taken Date07/16/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing07/21/2020
Sample typeAcceptance A brief description of the sampleASTM A722 All-Thread-Bar (150 ksi)
The quantity of what the sample constitutes2 (2-1/2") dia threaded bars From where was the sample collectedFabricator
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Inspector Telephone number of sampler707-342-8602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWilliams Form Eng Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar Type Rebar Size
Nut Specification for Threaded BarNA System ManufacturerWilliams Form Eng
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)100100435
Nut Heat Number(s)NA Bar Lot NumberNA
Nut Lot NumberNA Coupler Heat Number(s)NA
Coupler GradeNA

Test Details

DIME Sample ID: 2020-07-16-2
DIME Test ID: 2020-07-16-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2020-07-27

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 07/24/2020
UTM: 2000kip
Temperature: 72 f
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
11ASTM A722 Type II Deformed Bar 2 1/2 : 65mm1001004354.907163795.50149.83041.1A722 Barfsaylor

General comments (publicly viewable) (Max 1000 characters): A722 Bar
Test Graph
Source: Bluehill Data Point File
WARNING: strain or stress not found in data points imported from Instron machine.

Test was verified on 7/27/2020