Summary for Test 2020-07-09-12-1

Test performed: ASTM C39-10

Project Information

Project IdentifiersProject ID: 214511
DEA: 010E0004
EFIS: 0113000091
DIST-CO-RTE-PM01-HUM-101-84.4/84.8
Award Date01/29/2020
Closeout Date11/22/2023
Work DescriptionBRIDGE RAIL REPLACEMENT.
Location DescriptionHUMBOLDT COUNTY NEAR ARCATA FROM JACOBY CREEK BRIDGE TO GANNON SLOUGH BRIDGE
QA Service Level1 (Verified on 11/13/2019)

Sample Information

Sample Taken Date07/09/2020 Sample Unique Key12
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/10/2020
Sample typeQuality Control A brief description of the sample6x12 concrete cylinders
The quantity of what the sample constitutes2 6x12 Cylinders From where was the sample collectedManufacturer
First name of sampler or witnessed byMark Patrick Last name of sampler or witnessed byBaddu
Title of samplerQC Inspector Telephone number of sampler
Laboratory sample identification7-9-20-B1B Linked DIME Sample ID
The fabricator/manufacturer/facility nameCon-Fab California, LLC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameJacoby Creek

Material Information

Material TypeConcrete The concrete mix design number85LV20F5S
The truck number from where the sample was collected2nd The batch plant ticket number from where the sample was collected1914
Concrete batch plantBP1 The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedBed 1B, 2nd Truck Where the material sample would have been placed if not sampledCasting Bed
From Lot No.Unknown Bag Lot No.Unknown

Test Details

DIME Sample ID: 2020-07-09-12
DIME Test ID: 2020-07-09-12-1
Testing Lab: Con-Fab California Corporation - Lathrop
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2020-07-10

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Ferdinand Rosal
Date of test: 07/10/2020
Capped in accordance with?: ASTM C1231
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 144600 lb
Maximum load on cylinder 2: 143000 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 1 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength (to nearest 10 psi): 5090 psi
General comments (publicly viewable) (Max 1000 characters):