Summary for Test 2020-06-23-7-2

Test performed: ASTM A775-07b-re14

Project Information

Project IdentifiersProject ID: 77777
DEA: CHEM-STOCK
EFIS: CHEM-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/23/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/09/2020
Sample typeAcceptance A brief description of the sample#10 A775
The quantity of what the sample constitutes19422lbs From where was the sample collectedSource
First name of sampler or witnessed byKevin Last name of sampler or witnessed byMuser
Title of samplerQA Telephone number of sampler9165170532
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameWestern Coatings Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)1201023452
Rebar Epoxy Batch Number(s)WD19527NA Rebar Coating SpecificationASTM A775
Rebar Size (#)10 Rebar Coating ColorGreen
Rebar ManufacturerCMC Arizona Rebar CoaterWestern Coating Ogden UT
Rebar Powder ManufacturerAzkoNoble Release NumberAudit
Quality Assurance Code

Test Details

DIME Sample ID: 2020-06-23-7
DIME Test ID: 2020-06-23-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2020-07-14

Test Results


Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 07/09/2020
Lower spec. limit LSL: 7
Upper spec. limit USL: 16
Bar # for First Bar: 1
Bar # for Second Bar: 2
First Bar Side 1 mean value: 10.94
First Bar Side 2 mean value: 11.06
Second Bar Side 1 mean value: 11.57
Second Bar Side 2 mean value: 11.02
First Bar Mean: 11
Second Bar Mean: 11.3
Total mean value: 11.15
General comments (publicly viewable) (Max 1000 characters): Appears to have Excessive Nicks in Epoxy. Bars Rapped lose in Box.

Test was verified on 7/14/2020