Summary for Test 2014-11-25-2-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 7826 DEA: 040A1854 EFIS: 0400020652 COOP: 042363 |
---|---|
DIST-CO-RTE-PM | 04-SON-101-7.1/8.1 |
Award Date | 02/12/2013 |
Closeout Date | 01/03/2017 |
Work Description | RECONSTRUCT INTERCHANGE |
Location Description | SONOMA COUNTY IN PETALUMA FROM 0.6 MILE SOUTH TO 0.4 MILE NORTH OF OLD REDWOOD HIGHWAY OVERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 11/25/2014 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/05/2014 |
Sample type | Quality Control | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Source |
First name of sampler or witnessed by | Andrew | Last name of sampler or witnessed by | G |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | na | Transportation Laboratory (TL) Number | 052732 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Unknown | |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | 4201A |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | na |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | na | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2014-11-25-2
DIME Test ID: 2014-11-25-2-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-12-23
Test Results
Unit system used?: US Units
Number of specimens: 4
Test performed: With no density determined
Input Type: Measured
Tester's full name: SV
Date of test: 12/23/2014
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 6.00 in
Average diameter of cylinder 4: 6.00 in
Maximum load on cylinder 1: 152033 lb
Maximum load on cylinder 2: 149647 lb
Maximum load on cylinder 3: 152233 lb
Maximum load on cylinder 4: 147014 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Type of fracture pattern of cylinder 4: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Correction factor for cylinder 3: no data
Correction factor for cylinder 4: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Cross sectional area of cylinder 4: 28.27 in^2
Compressive strength of cylinder 1: 5412.4 psi
Compressive strength of cylinder 2: 5327.4 psi
Compressive strength of cylinder 3: 5385 psi
Compressive strength of cylinder 4: 5200.4 psi
Compressive strength (to nearest 10 psi): 5330 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 4
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 4
Source: Partner Data Point File
Test graph for Cylinder Code 3 of 4
Source: Partner Data Point File
Test graph for Cylinder Code 4 of 4
Test was verified on 12/23/2014 ✔