Summary for Test 2020-06-08-37-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213835 DEA: 051F7404 EFIS: 0514000049 |
---|---|
DIST-CO-RTE-PM | 05-MON-101-R28.0/R30.6 |
Award Date | 04/03/2019 |
Closeout Date | 08/23/2021 |
Work Description | PLACE CONTINUOUSLY REINFORCED CONCRETE PAVEMENT ON EXISTING ROADWAY. |
Location Description | MONTEREY COUNTY NEAR SAN LUCAS FROM 0.1 MILE SOUTH OF PARIS VALLEY ROAD OVERCROSSING TO RANCHO UNDERCROSSING |
QA Service Level | 1 (Verified on 02/18/2019) |
Sample Information
Sample Taken Date | 06/08/2020 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/19/2020 |
Sample type | Verification | A brief description of the sample | Bag of RAP |
The quantity of what the sample constitutes | One JMF Renewal | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Larry | Last name of sampler or witnessed by | Scott |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | SPM Templeton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Templeton |
---|---|---|---|
Aggregate Size | Unknown | Aggregate Source | Unknown |
RAP Stockpile | Stockpile Size (tons) | Unknown | |
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-08-37
DIME Test ID: 2020-06-08-37-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-07-02
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: E. Atkins
Date of test: 06/23/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1528.1 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 6.33 %
General comments (publicly viewable) (Max 1000 characters): Subtract 2.17 for equivalent ASTM D 2172 value.
Test was verified on 7/2/2020 ✔