Summary for Test 2020-05-14-50-1

Test performed: AASHTO T240-17

Project Information

Project IdentifiersProject ID: 214589
DEA: 020J1604
DIST-CO-RTE-PM02-PLU-284-0.0/8.3
Award Date02/11/2020
Closeout Date10/06/2020
Work DescriptionPLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING).
Location DescriptionPLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date05/14/2020 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2020
Sample typeDepartment Acceptance A brief description of the sampleAsphalt Binder
The quantity of what the sample constitutes1 Can, #1 Test From where was the sample collectedSource
First name of sampler or witnessed byJ Last name of sampler or witnessed byMontana
Title of sampler Telephone number of sampler
Laboratory sample identificationAB206041 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMarathan Transportation Laboratory (TL) Number733193
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot numberNot set
Sublot numberNot set Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Certified Asphalt SupplierNot set MultigradeNot set
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-14-50
DIME Test ID: 2020-05-14-50-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2020-07-01

Test Results


Is mass change based on one or two containers?: One
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 07/01/2020
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 168.790 grams
Mass of container #1 before test (m1i): 204.270 grams
Mass of container #1 after test (m1f): 204.100 grams
Average mass change: -0.479 percent
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2020