Summary for Test 2020-05-20-35-10

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/20/2020 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/21/2020
Sample typeAggregate Prequalification Program A brief description of the sampleHMA - 1/4" Bin
The quantity of what the sample constitutes3 Buckets From where was the sample collectedSource
First name of sampler or witnessed byPlant Last name of sampler or witnessed byTechnician
Title of sampler Telephone number of sampler
Laboratory sample identification20-0087 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock - AR Wilson Quarry Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-35-0012::A.R. WILSON QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-20-35
DIME Test ID: 2020-05-20-35-10
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2020-07-01

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Measured
Tester's full name: Jay Horton
Date of test: 06/15/2020
Cumulative Mass RetainedCumulative Percent Passing
1139.8 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
19.1 grams98.3 %
341.4 grams70 %
669.5 grams11.3 %
743.5 grams4.8 %
762.0 grams3.2 %
770.9 grams2.4 %
777.3 grams1.8 %
782.7 grams1.38 %
grams
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/1/2020