Summary for Test 2020-05-07-25-3
Test performed: AASHTO T312-14Project Information
Project Identifiers | Project ID: 214589 DEA: 020J1604 |
---|---|
DIST-CO-RTE-PM | 02-PLU-284-0.0/8.3 |
Award Date | 02/11/2020 |
Closeout Date | 10/06/2020 |
Work Description | PLACE HMA (TYPE A), PRECOATED AGGREGATE (SEAL COAT), HMA (LEVELING). |
Location Description | PLUMAS COUNTY NEAR CHILCOOT FROM ROUTE 70 TO 1 MILE NORTH OF LITTLE LAST CHANCE CREEK BRIDGE NUMBER 09-0072 |
QA Service Level | 1 (Verified on 01/22/2020) |
Sample Information
Sample Taken Date | 05/07/2020 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/08/2020 |
Sample type | Verification | A brief description of the sample | 1/2-inch Type A HMA (eq. PG 64-28 M), 25.0 RAP, 1.0 Lime |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jimmy | Last name of sampler or witnessed by | Montana |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78422 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Ward Lake Plant, Litchfield, CA | Transportation Laboratory (TL) Number | 733189 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-07-25
DIME Test ID: 2020-05-07-25-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)
Test Release Date: 2020-06-29
Test Results
HMA Type: Type A HMA
Is this test used for JMF verification:
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 05/11/2020
Start time of test (military time): 1251
Specimen identification: 2051105
Percent Binder Content: 6.6 %
Average diameter of the mold: 150 mm
Height of the extruded specimen (Hm): 113.8 mm
Mass of the specimen: 4564.2 g
Maximum Specific Gravity (Gmm): 2.393
Bulk Specific Gravity (Gmb): 2.345
Unit weight of water: 1 g/cm^3
Gyration Angle: 1.16 deg
Gyration Angle: 20.2 mrad
Method used to verify gyration angle: AASHTO T 344 at room temperature
Uncorrected relative density (Gmmu8): 84.8 %
Uncorrected relative density (Gmmu85): 93.7 %
Uncorrected relative density (Gmmu130): 94.9 %
Air Voids (AV8): 12.5 %
Air Voids (AV85): 3.3 %
Air Voids (AV130): 2.0 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/29/2020 ✔