Summary for Test 2020-05-31-10-10

Test performed: CTM 229-June 2011

Project Information

Project IdentifiersProject ID: 213970
DEA: 080K1214
EFIS: 0815000245
DIST-CO-RTE-PM08-SBD-15-12.5/14.8
Award Date12/23/2019
Closeout Date01/18/2022
Work DescriptionREPLACE PCC PAVEMENT WITH JPCP AND PRECAST JOINTED CONCRETE PAVEMENT.
Location DescriptionSAN BERNARDINO COUNTY IN FONTANA AND NEAR DEVORE FROM 0.3 MILE SOUTH OF SIERRA AVENUE UNDERCROSSING TO GLEN HELEN PARKWAY UNDERCROSSING
QA Service Level1 (Verified on 12/12/2019)

Sample Information

Sample Taken Date05/31/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/02/2020
Sample typeAnnual Source Testing A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byHindman
Title of samplerQC Technician Telephone number of sampler951-236-2183
Laboratory sample identification1153 Linked DIME Sample ID
The fabricator/manufacturer/facility nameRobertsons-Rialto Transportation Laboratory (TL) Number1153
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0146
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedRobertson Rialto
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-31-10
DIME Test ID: 2020-05-31-10-10
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 229-June 2011: Method of Test for Durability Index
Test Release Date: 2020-06-29

Test Results


What test(s) are being run?: Fine durability only
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/18/2020
Fine durability index: 84
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/29/2020