Summary for Test 2020-06-15-19-7
Test performed: ASTM D4791-10Project Information
Project Identifiers | Project ID: 213603 DEA: 07301504 EFIS: 0714000020 |
---|---|
DIST-CO-RTE-PM | 07-LA-1,10-R34.6/35.2,R2.1/18.4 |
Award Date | 11/19/2018 |
Closeout Date | 01/18/2022 |
Work Description | REPLACING CONCRETE AND AC PAVEMENT |
Location Description | LOS ANGELES COUNTY IN SANTA MONICA AND LOS ANGELES ON ROUTE 1 FROM 0.1 MILE WEST OF MAIN STREET OVERCROSSING TO ROUTE 1/10 SEPARATION AND ON ROUTE 10 FROM ROUTE 1/10 SEPARATION TO ROUTE 5/10 SEPARATION AND AT ROUTE 10/110 SEPARATION |
QA Service Level | 1 (Verified on 07/26/2019) |
Sample Information
Sample Taken Date | 06/15/2020 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/23/2020 |
Sample type | Department Acceptance | A brief description of the sample | 1/2" RHMA-G-SP 0.5% LAS |
The quantity of what the sample constitutes | 4 bags colfeed agg. | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Vulcan Irvindale | Last name of sampler or witnessed by | Julio Martinez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0361G-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Fish Canyon - Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0035::FISH CANYON QUARRY |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Conveyor Belt |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1/2 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-15-19
DIME Test ID: 2020-06-15-19-7
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-06-26
Test Results
Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles
Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 06/25/2020
Weighted percentage of particles (by mass) that were flat and elongated: 0 %
Weighted percentage of particles (by mass) that were not flat and elongated: 100 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/26/2020 ✔