Summary for Test 2020-05-04-33-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214516
DEA: 024H2404
EFIS: 0218000098
DIST-CO-RTE-PM02-TRI-3-32.0/38.0,53.7/63.8
Award Date12/23/2019
Closeout Date02/18/2021
Work DescriptionPLACE HMA (TYPE A) OVERLAY, SHOULDER BACKING, AND TRAFFIC STRIPE.
Location DescriptionTRINITY COUNTY NEAR WEAVERVILLE FROM 0.4 MILE NORTH OF BROWNS RANCH ROAD TO 0.1 MILE NORTH OF RUSH CREEK ROAD AND FROM EAST FORK STUART BRIDGE TO 2.4 MILES NORTH OF EL DORADO WAY
QA Service Level1 (Verified on 01/22/2020)

Sample Information

Sample Taken Date05/04/2020 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/04/2020
Sample typeDepartment Acceptance A brief description of the sample1/2-inch Type A HMA (PG 64-16) 15.0 RAP, 1.3 Lime
The quantity of what the sample constitutesUp to Five Days Paving From where was the sample collectedManufacturer
First name of sampler or witnessed byDorell Last name of sampler or witnessed byHarper
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD78416 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNorthstate Asphalt, Redding, CA Transportation Laboratory (TL) Number002552
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot numberUnknown
Sublot numberUnknown HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-04-33
DIME Test ID: 2020-05-04-33-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-06-23

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 05/05/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1559.3 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.66 %
Moisture Content: 0 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.4 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/23/2020