Summary for Test 2020-05-07-18-4

Test performed: ASTM D4791-10

Project Information

Project IdentifiersProject ID: 212899
DEA: 051C6704
EFIS: 0512000194
DIST-CO-RTE-PM05-SCR-17-0.2-0.5
Award Date02/08/2019
Closeout Date09/23/2022
Work DescriptionPASATIEMPO RETAINING WALL -
Location DescriptionIN SANTA CRUZ FROM 0.5 MILE TO 0.3 MILES SOUTH OF PASATIEMPO OVERCROSSING
QA Service Level1 (Verified on 04/01/2019)

Sample Information

Sample Taken Date05/07/2020 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/29/2020
Sample typeVerification A brief description of the sampleBags of Aggregate
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byDoug Last name of sampler or witnessed byLemon
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGraniterock Aromas Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collected91-35-0012
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-07-18
DIME Test ID: 2020-05-07-18-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2020-06-17

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: B
Determination: By Mass
Dimensional ratio used: 5:1
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 06/16/2020
Weighted percentage of particles (by mass) that were flat and elongated: 0 %
Weighted percentage of particles (by mass) that were not flat and elongated: 100 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/17/2020