Summary for Test 2020-05-02-10-5
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 66666 DEA: APP EFIS: 0019000052 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 05/02/2020 | Sample Unique Key | 10 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/20/2020 |
Sample type | Aggregate Prequalification Program | A brief description of the sample | 3/8 Pea Gravel |
The quantity of what the sample constitutes | 150 lbs 6 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Mike | Last name of sampler or witnessed by | Maldonado |
Title of sampler | QC Tech | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | 2020-03-04-15 | |
The fabricator/manufacturer/facility name | Vulcan Materials Reliance | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA or name of Pit) | 91-19-0016::RELIANCE - IRWINDALE |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Unknown |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | HMA Design ID |
Test Details
DIME Sample ID: 2020-05-02-10
DIME Test ID: 2020-05-02-10-5
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-06-24
Test Results
What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Measured
Tester's full name: Nader Rashidi-Ghader
Date of test: 05/19/2020
Cumulative mass retained on the 1/2 in. sieve: 6 grams
Cumulative mass retained on the 3/8 in. sieve: 686 grams
Cumulative mass retained on the #4 sieve: 12200 grams
Cumulative mass retained on the #8 sieve: 14378 grams
Cumulative mass retained on the pan: 14820 grams
Mass of all aggregate: 14820 grams
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:95 %
Cumulative percent passing the #4 sieve:18 %
Cumulative percent passing the #8 sieve:3 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/24/2020 ✔