Summary for Test 2020-02-12-43-3

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/12/2020 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/13/2020
Sample typeAggregate Prequalification Program A brief description of the sample3/8" Pea Gravel
The quantity of what the sample constitutes4 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byRene Last name of sampler or witnessed byMorquecho
Title of samplerQC Technician Telephone number of sampler559-416-3147
Laboratory sample identification20-APPC-0063 Linked DIME Sample ID2020-2-12-37
The fabricator/manufacturer/facility nameCEMEX - Rockfield Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-10-0014::ROCKFIELD PLANT
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-02-12-43
DIME Test ID: 2020-02-12-43-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2020-06-10

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 05/22/2020
Top sediment column reading (single primary size): 0.3 in
Cleanness value (single primary size): 91
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/10/2020