Summary for Test 2020-05-12-8-9
Test performed: CTM 202-November 2011Project Information
Project Identifiers | Project ID: 214523 DEA: 07302504 EFIS: 0713000479 |
---|---|
DIST-CO-RTE-PM | 07-VEN-23-R3.3/R11.5 |
Award Date | 02/06/2020 |
Closeout Date | 12/10/2024 |
Work Description | PLACE HMA AND JPCP AND INDIVIDUAL SLAB REPLACEMENT. |
Location Description | VENTURA COUNTY FROM ROUTE 101/23 SEPARATION TO NEW LOS ANGELES AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 03/17/2020) |
Sample Information
Sample Taken Date | 05/12/2020 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2020 |
Sample type | Verification | A brief description of the sample | 3/4 HMA-A-SP R15 Aggregate and RAP |
The quantity of what the sample constitutes | JMF 12 Bags | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jay | Last name of sampler or witnessed by | Olsen |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0242A-20 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials Sun Valley | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0017, 91-19-0019, 91-19-0021 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | 3/4 HMA-A-SP R15 | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | 220831 SVA MPC | A detailed description of where the material sample was collected | Belt Cut at Vulcan Sun Valley Plant |
Where the material sample would have been placed if not sampled | Asphalt Paving | Primary Aggregate Nominal Size | 3/4 inch |
The concrete mix design number | Unknown | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-12-8
DIME Test ID: 2020-05-12-8-9
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-06-02
Test Results
What size aggregate is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Michael Magana
Date of test: 05/22/2020
Cumulative percent passing the 3 in. sieve: 100 %
Cumulative percent passing the 2 1/2 in. sieve: 100 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 99 %
Cumulative percent passing the #4 sieve: 82 %
Cumulative percent passing the #8 sieve: 65 %
Cumulative percent passing the #16 sieve: 51 %
Cumulative percent passing the #30 sieve: 38 %
Cumulative percent passing the #50 sieve: 26 %
Cumulative percent passing the #100 sieve: 17 %
Cumulative percent passing the #200 sieve: 10.9 %
General comments (publicly viewable) (Max 1000 characters): RAP Gradation After Ignition Oven