Summary for Test 2020-05-14-35-4

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 213733
DEA: 051C85U4
EFIS: 0518000156
DIST-CO-RTE-PM05-SCR-1-10.2/17.5
Award Date02/19/2019
Closeout Date11/15/2021
Work DescriptionSanta Cruz 1 CAPM and Bridge Rails
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ FROM NORTH APTOS UNDERPASS TO JUNCTION ROUTE 9.
QA Service Level1 (Verified on 02/14/2019)

Sample Information

Sample Taken Date05/14/2020 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/15/2020
Sample typeVerification A brief description of the sampleBags of Virgin Aggregate
The quantity of what the sample constitutesOne JMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byAnthony Last name of sampler or witnessed byRomiza
Title of samplerField Inspector Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Salinas Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-27-0028::HANDLEY RANCH QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-05-14-35
DIME Test ID: 2020-05-14-35-4
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-05-20

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: Daniel Gingras
Date of test: 05/19/2020
Sand Equivalent (Test 1): 76
Sand Equivalent (Test 2): 70
Sand Equivalent (Test 3): 73
Sand Equivalent: 73
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/20/2020