Summary for Test 2020-05-01-5-1
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 213229 DEA: 050A0504 EFIS: 0500000007 |
---|---|
DIST-CO-RTE-PM | 05-SB-1-15.6 |
Award Date | 12/14/2018 |
Closeout Date | 08/17/2022 |
Work Description | BRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE. |
Location Description | SANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/23/2018) |
Sample Information
Sample Taken Date | 05/01/2020 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 05/11/2020 |
Sample type | Quality Assurance | A brief description of the sample | (1) .6"Ø 4 ft. Long |
The quantity of what the sample constitutes | (1 pack) .6"Ø 8,900 ft. Long | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
Title of sampler | QA | Telephone number of sampler | 951-500-0685 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | OLDCAST PRECAST PERRIS | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-074-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | S335292-1 | Number of Coils | 1 |
Group Number | Strand Diameter | .6 in | |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0579519-2 | Mfg. Lot Number(s) | S335292-1 |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2020-05-01-5
DIME Test ID: 2020-05-01-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2020-05-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 05/05/2020
UTM: 120kip
Temperature: 72 f
Extensometers: no data
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0579519-2 | S335292-1 | 0.214 | 59580 | 54864.3 | 27.9 | 1.76 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 5/6/2020 ✔