Summary for Test 2020-04-29-10-5

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214421
DEA: 01362704
EFIS: 0116000031
DIST-CO-RTE-PM01-MEN-1-62.2/R78.9
Award Date12/23/2019
Closeout Date03/09/2021
Work DescriptionHOT MIX ASPHALT OVERLAY.
Location DescriptionMENDOCINO COUNTY NEAR FORT BRAGG FROM 0.1 MILE NORTH OF PUDDING CREEK BRIDGE TO 0.6 MILE NORTH OF WAGES CREEK BRIDGE
QA Service Level1 (Verified on 09/19/2019)

Sample Information

Sample Taken Date04/29/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/29/2020
Sample typeQuality Assurance A brief description of the sampleHVY Hex Nut A194
The quantity of what the sample constitutes9 From where was the sample collectedJob Site
First name of sampler or witnessed byDave Last name of sampler or witnessed byGunderson
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNingbo Haixin Hardware Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s) Nut Mfg. Lot Number(s)5143250008
Washer Mfg. Lot Number(s) Bolt SpecificationNA
Bolt Length(s)Unknown Nut SpecificationA194 2H
Washer SpecificationNA Finish
Diameter/Size3/4 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)Blue

Test Details

DIME Sample ID: 2020-04-29-10
DIME Test ID: 2020-04-29-10-5
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-04-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/29/2020
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11E514325000858693Proof Loadfsaylor

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 4/30/2020