Summary for Test 2020-04-28-2-1

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 214278
DEA: 060V9104
EFIS: 0617000062
DIST-CO-RTE-PM06-FRE,KER,KIN,MAD,TUL-5,41,99,184-Var
Award Date09/27/2019
Closeout Date04/04/2022
Work DescriptionINSTALL ZERO EMISSIONS VEHICLE CHARGING STATIONS.
Location DescriptionFRESNO, KERN, KINGS, MADERA, AND TULARE COUNTIES AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/29/2019)

Sample Information

Sample Taken Date04/28/2020 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/28/2020
Sample typeQuality Assurance A brief description of the sampleAnchor Bolt Assembly
The quantity of what the sample constitutes1 Anchor Bolt, 8 Hexagonal Nuts, 8 Washers From where was the sample collectedOther
First name of sampler or witnessed byNathan Last name of sampler or witnessed byStrid
Title of samplerAssistant METS Representative Telephone number of sampler5593130079
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePortland Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)A195747 Nut Mfg. Lot Number(s)32150-190840
Washer Mfg. Lot Number(s)0120-341 Bolt SpecificationASTM F1554
Bolt Length(s)36" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishHot Dip Galv
Diameter/Size1" Bolt Mfg. Lot Number348912
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2020-04-28-2
DIME Test ID: 2020-04-28-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-04-30

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/29/2020
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
1132150-19084094829Proof Loadfsaylor

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 4/30/2020