Summary for Test 2020-04-22-2-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214923 DEA: 081L7104 EFIS: 0820000141 |
---|---|
DIST-CO-RTE-PM | 08-RIV-91-10.29 |
Award Date | 04/13/2020 |
Closeout Date | 01/14/2021 |
Work Description | Bridge Repair |
Location Description | Not set |
QA Service Level | 1 (Verified on 04/21/2020) |
Sample Information
Sample Taken Date | 04/22/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/23/2020 |
Sample type | Quality Assurance | A brief description of the sample | Mechanical Couplers |
The quantity of what the sample constitutes | Lot 1 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Weeks |
Title of sampler | ASI | Telephone number of sampler | 310-883-8369 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Integrity Rebar | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L79-016-20 | Structure unique identifier | |
Structure name | Buchanan St OC |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Casacade |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Integrity Rebar |
Rebar Size | #5 | Coupler Model | Zap Screwlok Type 2 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | NA | Rebar Hoop Fabricator | NA |
Coupler Component Heat/Lot Number(s) | A143646 Code EE | Rebar Heat Number(s) | 124819 |
Rebar Size 2 | 5 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2020-04-22-2
DIME Test ID: 2020-04-22-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-04-23
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/23/2020
UTM: 400kip
Temperature: 72.00 f
Halo ID: Small
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|---|
1 | 1 | No. 5/16mm | 1 | -0.0024 | 0.31 | 27508 | 88735 | Service Splice | bewing |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 4/23/2020 ✔