Summary for Test 2020-04-20-8-4
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 212244 DEA: 044G8404 EFIS: 0413000051 |
---|---|
DIST-CO-RTE-PM | 04-NAP-128-20.1/20.4 |
Award Date | 02/19/2019 |
Closeout Date | 06/27/2023 |
Work Description | REPLACE CAPELL CREEK BRIDGE |
Location Description | NAPA COUNTY ABOUT 15 MILES EAST OF RUTHERFORD FROM 1.1 MILES EAST OF KNOXVILLE ROAD TO 0.3 MILE WEST OF CAPELL VALLEY CREST |
QA Service Level | 1 (Verified on 05/20/2017) |
Sample Information
Sample Taken Date | 04/20/2020 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/22/2020 |
Sample type | Quality Assurance | A brief description of the sample | A325 Bolt |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Matt | Last name of sampler or witnessed by | Abel |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | ||
Washer Mfg. Lot Number(s) | Bolt Specification | F3125 | |
Bolt Length(s) | 4.5 | Nut Specification | Unknow |
Washer Specification | Unknow | Finish | A2329 |
Diameter/Size | 1 | Bolt Mfg. Lot Number | AB547A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-04-20-8
DIME Test ID: 2020-04-20-8-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-04-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 04/23/2020
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1 | AB547A | 93982 | Nut Proof | bewing |
General comments (publicly viewable) (Max 1000 characters): Nut Proof
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 4/23/2020 ✔