Summary for Test 2020-04-01-1-11
Test performed: ASTM B499-14Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/01/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/01/2020 |
Sample type | Stock | A brief description of the sample | 3/4" x 10-1/2" F1554 Grade 55-S1/A153/F2329 All Thread Chisel Point |
The quantity of what the sample constitutes | 1,003 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 1 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1201014406 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | F1554 Grade 55-S1 / A153 / F2329 | |
Bolt Length(s) | 10-1/2" | Nut Specification | n/a |
Washer Specification | n/a | Finish | HDG |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 120101440660 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-04-01-1
DIME Test ID: 2020-04-01-1-11
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-04-09
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 04/09/2020
Sample No.: 1D
Rocap Number: F1554
Heat Number(s): 120101440660
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: YELLOW PAINT
Size: .750 in
Bolt Length: 10.5 in
Measurement Average: 5.53 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2020 ✔