Summary for Test 2020-04-01-3-14
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 210037 DEA: 043G4424 EFIS: 0412000042 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-R5.6/7.6 |
Award Date | 03/22/2018 |
Closeout Date | 07/24/2023 |
Work Description | WEST SPAN DAMPER BRACKET A325 BOLT TESTING |
Location Description | SFOBB WEST SPAN |
QA Service Level | 1 (Verified on 11/04/2014) |
Sample Information
Sample Taken Date | 04/01/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/06/2020 |
Sample type | Quality Assurance | A brief description of the sample | A325 Fasteners |
The quantity of what the sample constitutes | 310 ea | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-022-20 | Structure unique identifier | |
Structure name | SFOBB |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 1188-01 |
---|---|---|---|
Heat Number(s) | bolt-10629590 washer- 163050 nut- DL18104889 | Nut Mfg. Lot Number(s) | Nut- 416921B |
Washer Mfg. Lot Number(s) | Washer- 141843 | Bolt Specification | A325 |
Bolt Length(s) | 3 1/2" | Nut Specification | F563 |
Washer Specification | F436 | Finish | Galv |
Diameter/Size | 1" | Bolt Mfg. Lot Number | L569M1 |
Rocap Test Requirement(s) | yes | Lubricant Requirements(s) | yes |
Test Details
DIME Sample ID: 2020-04-01-3
DIME Test ID: 2020-04-01-3-14
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-04-09
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 04/09/2020
Sample No.: 1E
Rocap Number: 1188-01
Heat Number(s): no data
Mfg. Lot Number: L569M1
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: LE USA A325
Size: 1 in
Bolt Length: 3.5 in
Measurement Average: 3.45 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/9/2020 ✔