Summary for Test 2020-02-14-28-5
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214520 DEA: 051H9804 EFIS: 0517000043 |
---|---|
DIST-CO-RTE-PM | 05-SB-101-78.4/79.0 |
Award Date | 01/08/2020 |
Closeout Date | 09/25/2020 |
Work Description | ROADWAY EXCAVATION, PLACE AGGREGATE BASE, HMA AND RHMA-G. |
Location Description | SANTA BARBARA COUNTY NEAR SANTA MARIA FROM 0.3 MILE SOUTH TO 0.3 MILE NORTH OF SOLOMON SUMMIT UNDERCROSSING |
QA Service Level | 1 (Verified on 02/20/2020) |
Sample Information
Sample Taken Date | 02/14/2020 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/14/2020 |
Sample type | Quality Control | A brief description of the sample | Lab Mixed HMA |
The quantity of what the sample constitutes | 15 kg | From where was the sample collected | Other |
First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Ortega |
Title of sampler | Lab Supervisor | Telephone number of sampler | 805-345-3425 |
Laboratory sample identification | 755727228 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CalPortland Santa Maria | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-02-14-28
DIME Test ID: 2020-02-14-28-5
Testing Lab: CalPortland
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-04-03
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ryan Deveraux
Date of test: 02/14/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1500.0 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 5.90 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/3/2020 ✔