Summary for Test 2020-03-12-1-3
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 212244 DEA: 044G8404 EFIS: 0413000051 |
---|---|
DIST-CO-RTE-PM | 04-NAP-128-20.1/20.4 |
Award Date | 02/19/2019 |
Closeout Date | 06/27/2023 |
Work Description | REPLACE CAPELL CREEK BRIDGE |
Location Description | NAPA COUNTY ABOUT 15 MILES EAST OF RUTHERFORD FROM 1.1 MILES EAST OF KNOXVILLE ROAD TO 0.3 MILE WEST OF CAPELL VALLEY CREST |
QA Service Level | 1 (Verified on 05/20/2017) |
Sample Information
Sample Taken Date | 03/12/2020 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/12/2020 |
Sample type | Quality Assurance | A brief description of the sample | 1" x 38" A449/A153 Hex Bolts |
The quantity of what the sample constitutes | 5 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 916-8266371 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | UIS Lindon UT | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-009-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 62150150-07 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A449/A153 | |
Bolt Length(s) | 38 inchs | Nut Specification | n/a |
Washer Specification | n/a | Finish | HDG |
Diameter/Size | 1 inch | Bolt Mfg. Lot Number | 52486 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-03-12-1
DIME Test ID: 2020-03-12-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-04-02
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 04/01/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 62150150-07
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A 449 G
Size: 1 in
Bolt Length: 38 in
Measurement Average: 5.76 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/2/2020 ✔