Summary for Test 2020-03-11-7-2
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214315 DEA: 081G2104 EFIS: 0815000170 |
---|---|
DIST-CO-RTE-PM | 08-SBD-210 - 15,210-7.4/9.0, 10.5/12.7 |
Award Date | 10/01/2019 |
Closeout Date | 09/15/2021 |
Work Description | Install lighting and ramp metering systems. |
Location Description | Not set |
QA Service Level | 1 (Verified on 12/10/2019) |
Sample Information
Sample Taken Date | 03/11/2020 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/16/2020 |
Sample type | Quality Assurance | A brief description of the sample | Anchor Bolt Assembly |
The quantity of what the sample constitutes | 25 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | CT METS QA INSPECTOR | Telephone number of sampler | 916-826-6371 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | EDSCO Fasteners | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-007-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3086612 | Nut Mfg. Lot Number(s) | DDYD |
Washer Mfg. Lot Number(s) | 249368 | Bolt Specification | F1554 Gr. 55 |
Bolt Length(s) | 4 ft x 4 in | Nut Specification | A563 HDG A194 Gr. 2H Plain |
Washer Specification | F436 | Finish | Hot Dip Galvanized and Plain |
Diameter/Size | 1.50 in | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-03-11-7
DIME Test ID: 2020-03-11-7-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2020-04-02
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 03/26/2020
UTM: 400kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 2A | 27217-62144843 | 247533 | Nut Proof Load | spaine |
General comments (publicly viewable) (Max 1000 characters): Nut Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 4/2/2020 ✔