Summary for Test 2019-10-21-17-1

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214819
DEA: 07288304
EFIS: 0700021024
DIST-CO-RTE-PM07-LA-60,60,164,210-Var
Award Date03/01/2021
Closeout Date10/02/2023
Work DescriptionSTORM WATER MITIGATION
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 06/30/2021)

Sample Information

Sample Taken Date10/21/2019 Sample Unique Key17
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/29/2019
Sample typePreliminary A brief description of the sampleNATIVE SOIL DEPTH 0-25'
The quantity of what the sample constitutes1 BAG From where was the sample collectedJob Site
First name of sampler or witnessed byMOHAMMED Last name of sampler or witnessed byIQBAL
Title of samplerTE CIVIL Telephone number of sampler213-620-2339
Laboratory sample identification8791 Linked DIME Sample ID2019-10-21-17
The fabricator/manufacturer/facility nameNative Material Transportation Laboratory (TL) NumberA-19-001
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collected0 25FT DEPTH NATIVE SOIL
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-10-21-17
DIME Test ID: 2019-10-21-17-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-24

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: TESS PEREZ
Date of test: 11/13/2019
Soil sample resistance (lab measure 1): 8500 Ohms
Soil sample resistance (lab measure 2): 3600 Ohms
Soil sample resistance (lab measure 3): 3550 Ohms
Soil sample resistance (lab measure 4): 3550 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 3550 Ohms
Soil sample temperature: 21 C
Soil box constant: 1
pH of soil: 7.93
Minimum soil resistance corrected to 15.5: 4038 Ohms
Minimum soil resistivity at 15.5: 4038 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/24/2020