Summary for Test 2020-03-02-10-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/02/2020 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/16/2020
Sample typeAggregate Prequalification Program A brief description of the sample3/8" Concrete Aggregate
The quantity of what the sample constitutesproduction stockpile. From where was the sample collectedManufacturer
First name of sampler or witnessed byTrenton Last name of sampler or witnessed byCrouse
Title of samplerQC Supervisor Telephone number of sampler(209) 834-8316
Laboratory sample identification Linked DIME Sample ID2020-03-02-7
The fabricator/manufacturer/facility nameTeichert Materials Vernalis Transportation Laboratory (TL) Number20-APPC-0038
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-39-0041::VERNALIS WEST & EAST PROPERTIES
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile Loader Blend
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-03-02-10
DIME Test ID: 2020-03-02-10-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-04-08

Test Results


What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Ryan Kester
Date of test: 03/19/2020
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 86 %
Cumulative percent passing the #4 sieve: 6 %
Cumulative percent passing the #8 sieve: 0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/8/2020