Summary for Test 2019-12-19-28-2

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date12/19/2019 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/23/2019
Sample typeDepartment Acceptance A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes1 Bag From where was the sample collectedDistributor
First name of sampler or witnessed byTUAN A Last name of sampler or witnessed byNGUYEN
Title of samplerMREA Telephone number of samplerUnknown
Laboratory sample identification9048 Linked DIME Sample ID2019-12-19-28
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) NumberCTNT1
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)Unknown
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedUnknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberG3-19-PCC-001 Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-12-19-28
DIME Test ID: 2019-12-19-28-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-03-19

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: DANILLO FERRER
Date of test: 03/07/2020
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.9
Sand reading (test 1): 4.8
Clay reading (test 2): 5.2
Sand reading (test 2): 4.4
Sand equivalent (test 1): 82
Sand equivalent (test 2): 85
Sand equivalent before temperature correction: 84
Sand equivalent after temperature correction: 84
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/19/2020