Summary for Test 2020-02-04-25-4

Test performed: CTM 217-June 2011

Project Information

Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date02/04/2020 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/27/2020
Sample typeAggregate Prequalification Program A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes4 BAGS From where was the sample collectedSource
First name of sampler or witnessed byManolito Last name of sampler or witnessed byLimos
Title of samplerQUALITY CONTROL Telephone number of sampler
Laboratory sample identification9300 Linked DIME Sample ID2020-02-04-25
The fabricator/manufacturer/facility nameVulcan SHELDON Transportation Laboratory (TL) NumberC2019-12-06-11 DIME
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0017::SHELDON
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile @ Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-02-04-25
DIME Test ID: 2020-02-04-25-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-03-16

Test Results


Number of tests: 2
Input Type: Calculated
Tester's full name: LARRY DIAZ
Date of test: 02/14/2020
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5
Sand reading (test 1): 43
Clay reading (test 2): 4.9
Sand reading (test 2): 4.2
Sand equivalent (test 1): 86
Sand equivalent (test 2): 86
Sand equivalent before temperature correction: 86
Sand equivalent after temperature correction: 86
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/16/2020