Summary for Test 2019-07-22-49-1

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214698
DEA: 120N8904
EFIS: 1214000130
DIST-CO-RTE-PM12-ORA-133-8.3/M9.3
Award Date11/09/2023
Closeout DateNot set
Work DescriptionCONSTRUCT AUXILIARY LANE.
Location DescriptionORANGE COUNTY IN IRVINE FROM ROUTE 133/405 SEPARATION TO IRVINE CENTER DRIVE OVERCROSSING
QA Service Level1 (Verified on 02/22/2021)

Sample Information

Sample Taken Date07/22/2019 Sample Unique Key49
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2019
Sample typePreliminary A brief description of the sampleNATIVE SOIL 0- 40' DEPTH
The quantity of what the sample constitutes1 BAG From where was the sample collectedJob Site
First name of sampler or witnessed byBALA Last name of sampler or witnessed byKRISH
Title of sampler TE CIVIL Telephone number of sampler657-328-6546
Laboratory sample identification8872 Linked DIME Sample ID2019-07-22-49
The fabricator/manufacturer/facility nameNATIVE Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormA-19-005 BULK Structure unique identifier
Structure nameRTE 133 PM 8 5 PM 9 3

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRTE 133 PM 8.5 -9.3
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2019-07-22-49
DIME Test ID: 2019-07-22-49-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-03-13

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Calculated
Tester's full name: KIET PHAN
Date of test: 12/03/2019
Soil sample resistance (lab measure 1): 4100 Ohms
Soil sample resistance (lab measure 2): 2400 Ohms
Soil sample resistance (lab measure 3): 2400 Ohms
Soil sample resistance (lab measure 4): 2500 Ohms
Soil sample resistance (lab measure 5): no data Ohms
Soil sample resistance (lab measure 6): no data Ohms
Soil sample resistance (lab measure 7): no data Ohms
Soil sample resistance (lab measure 8): no data Ohms
Soil sample resistance (lab measure 9): no data Ohms
Soil sample resistance (lab measure 10): no data Ohms
Soil sample resistance (lab measure 11): no data Ohms
Soil sample resistance (lab measure 12): no data Ohms
Minimum soil resistance of the lab measurement: 2400 Ohms
Soil sample temperature: 21.1 C
Soil box constant: 1
pH of soil: 8.11
Minimum soil resistance corrected to 15.5: 2736 Ohms
Minimum soil resistivity at 15.5: 2736 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/13/2020