Summary for Test 2014-10-03-2-4
Test performed: CTM 301-March 2000Project Information
Project Identifiers | Project ID: 3951 DEA: 07202114 EFIS: 0700020869 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-17.2/26.4 |
Award Date | 04/04/2012 |
Closeout Date | 06/16/2021 |
Work Description | PAVE ROADWAY WITH LONG LIFE PAVEMENT AND WIDEN ROADWAY AND BRIDGES |
Location Description | LOS ANGELES COUNTY ON ROUTE 710 AT VARIOUS LOCATIONS FROM LOS ANGELES RIVER BRIDGE TO RAMONA BOULEVARD UNDERCROSSING |
QA Service Level | 1 (Verified on 11/27/2012) |
Sample Information
Sample Taken Date | 10/03/2014 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/06/2014 |
Sample type | Acceptance | A brief description of the sample | Max Class 3 Aggregate Base |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Sonny | Last name of sampler or witnessed by | Nogoy |
Title of sampler | Materials Tester | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | 3rd St On Ramp to NB 710 Stockpile | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | 3rd St On Ramp to NB 710 |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-10-03-2
DIME Test ID: 2014-10-03-2-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2015-02-20
Test Results
How will the R value be determined?: By expansion pressure
Input Type: Calculated
Tester's full name: Vincent Onoh
Date of test: 10/13/2014
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 98 %
As Received Gradation, Percent Passing 1 in. sieve: 96 %
As Received Gradation, Percent Passing 3/4 in. sieve: 89 %
As Received Gradation, Percent Passing 1/2 in. sieve: 71 %
As Received Gradation, Percent Passing 3/8 in. sieve: 60 %
As Received Gradation, Percent Passing #4 sieve: 42 %
As Received Gradation, Percent Passing #8 sieve: 33 %
As Received Gradation, Percent Passing #16 sieve: 27 %
As Received Gradation, Percent Passing #30 sieve: 21 %
As Received Gradation, Percent Passing #50 sieve: 14 %
As Received Gradation, Percent Passing #100 sieve: 9 %
As Received Gradation, Percent Passing #200 sieve: 6.3 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 80 %
As Used Gradation, Percent Passing 3/8 in. sieve: 67 %
As Used Gradation, Percent Passing #4 sieve: 47 %
As Used Gradation, Percent Passing #8 sieve: 37 %
As Used Gradation, Percent Passing #16 sieve: 30 %
As Used Gradation, Percent Passing #30 sieve: 23 %
As Used Gradation, Percent Passing #50 sieve: 16 %
As Used Gradation, Percent Passing #100 sieve: 10 %
As Used Gradation, Percent Passing #200 sieve: 7.1 %
R value: 78
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/20/2015 ✔