Summary for Test 2019-12-17-20-2

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 212600
DEA: 07293704
EFIS: 0713000239
DIST-CO-RTE-PM07-LA-110,405-8.0/9.0,12.2/13.2
Award Date02/27/2018
Closeout Date08/03/2023
Work DescriptionWIDEN SHOULDER AND AUXILIARY LANE OF CONNECTOR.
Location DescriptionLOS ANGELES COUNTY IN AND NEAR CARSON ON ROUTE 110 FROM 0.2 MILE NORTH OF TORRANCE BOULEVARD UNDERCROSSING TO 190TH STREET UNDERCROSSING AND ON ROUTE 405 FROM MAIN STREET UNDERCROSSING TO 190TH STREET UNDERCROSSING
QA Service Level1 (Verified on 04/03/2018)

Sample Information

Sample Taken Date12/17/2019 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/17/2019
Sample typeAcceptance A brief description of the sample3/8" PCC AGGREGATE
The quantity of what the sample constitutes1 BAG From where was the sample collectedManufacturer
First name of sampler or witnessed byHONESTO Last name of sampler or witnessed byCASTILLO
Title of samplerMREA Telephone number of sampler
Laboratory sample identification9018 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX READY MIX COMPTON PLANT Transportation Laboratory (TL) NumberC914423
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0106::WHITE MOUNTAIN QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedunknown
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-12-17-20
DIME Test ID: 2019-12-17-20-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2020-03-13

Test Results


Describe the gradation of the aggregate or the test method:: Mix of sizes - max 1.5 in.
Input Type: Calculated
Tester's full name: HUSNI ANKIR
Date of test: 12/24/2019
Cleanness value (11/2 in. maximum aggregate mix): 68
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/13/2020