Summary for Test 2020-02-26-2-6
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 213737 DEA: 07289104 EFIS: 0700021123 |
---|---|
DIST-CO-RTE-PM | 07-LA-405-11.9/13.2 |
Award Date | 01/09/2019 |
Closeout Date | 07/14/2022 |
Work Description | Rehabilitate the existing Commercial Vehicle Enforcement Facility. |
Location Description | LOS ANGELES COUNTY IN CARSON FROM DEL AMO BOULEVARD OVER CROSSING TO VERMONT AVENUE (190TH) UNDER CROSSING. |
QA Service Level | 1 (Verified on 08/26/2019) |
Sample Information
Sample Taken Date | 02/26/2020 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/03/2020 |
Sample type | Stock | A brief description of the sample | F1554 Grade 105 HDG Anchor Bolts |
The quantity of what the sample constitutes | 36 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA | Telephone number of sampler | 1-213-435-4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3083249 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | ASTM F1554 | |
Bolt Length(s) | Nut Specification | ASTM A563 | |
Washer Specification | ASTM F436-1 | Finish | Hot Dipped Galvanized |
Diameter/Size | 1 1/4" | Bolt Mfg. Lot Number | |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-02-26-2
DIME Test ID: 2020-02-26-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-03-10
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 03/06/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): 3083249
Mfg. Lot Number: no data
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: RED PAINT
Size: 1.250 in
Bolt Length: 18 in
Measurement Average: 6.49 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/10/2020 ✔