Summary for Test 2020-01-07-9-3

Test performed: CTM 643-June 2007

Project Information

Project IdentifiersProject ID: 214666
DEA: 022H8104
EFIS: 0217000012
DIST-CO-RTE-PM02-TRI-299-1.67/45.12
Award Date03/03/2022
Closeout Date08/11/2023
Work DescriptionTRINITY CULVERTS
Location DescriptionCULVERT REHABILITATION IN TRINITY COUNTY NEAR SALYER AT VARIOUS LOCATIONS FROM 0.1 MILE WEST OF WHITE HOUSE GULCH ROAD TO 0.4 MILE WEST OF SLATTERY POND ROAD.
QA Service Level1 (Verified on 03/02/2020)

Sample Information

Sample Taken Date01/07/2020 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2020
Sample typePreliminary A brief description of the sampleSoil for Use in Fill
The quantity of what the sample constitutesPreliminary Design From where was the sample collectedJob Site
First name of sampler or witnessed byScott Last name of sampler or witnessed byLewis
Title of samplerEngineering Geologist Telephone number of sampler
Laboratory sample identificationD78322 Linked DIME Sample ID
The fabricator/manufacturer/facility nameIn Situ Transportation Laboratory (TL) Number678221
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleField No. TC-1 A detailed description of where the material sample was collected02-TRI-299-8.19, Embankment on South Side, 6 - 12 inch Depth
Where the material sample would have been placed if not sampledUnknown

Test Details

DIME Sample ID: 2020-01-07-9
DIME Test ID: 2020-01-07-9-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-June 2007: Method for Determining Field and Laboratory Resistivity and pH Measurements for Soil and Water
Test Release Date: 2020-02-19

Test Results


The test method used?: Laboratory Resistivity Test for Soil
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 01/21/2020
Soil sample resistance (lab measure 1): 13500 Ohms
Soil sample resistance (lab measure 2): 4300 Ohms
Soil sample resistance (lab measure 3): 3675 Ohms
Soil sample resistance (lab measure 4): 3750 Ohms
Soil sample resistance (lab measure 5): no data
Soil sample resistance (lab measure 6): no data
Soil sample resistance (lab measure 7): no data
Soil sample resistance (lab measure 8): no data
Soil sample resistance (lab measure 9): no data
Soil sample resistance (lab measure 10): no data
Soil sample resistance (lab measure 11): no data
Soil sample resistance (lab measure 12): no data
Minimum soil resistance of the lab measurement: 3675 Ohms
Soil sample temperature: 20 C
Soil box constant: 1
pH of soil: 7.1
Minimum soil resistance corrected to 15.5: 4088.44 Ohm-cm
Minimum soil resistivity at 15.5: 4088 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/19/2020