Summary for Test 2020-01-08-21-2
Test performed: CTM 227-December 2014Project Information
Project Identifiers | Project ID: 212501 DEA: 022E4804 EFIS: 0200000586 |
---|---|
DIST-CO-RTE-PM | 02-SIS-96,263-103.1/103.6,56.8/57.2 |
Award Date | 12/14/2018 |
Closeout Date | 12/01/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | SISKIYOU COUNTY ABOUT 8 MILES NORTH OF YREKA ON ROUTE 96 FROM 0.5 MILE WEST TO 0.2 MILE EAST OF ROUTE 263 AND ON ROUTE 263 FROM 0.3 MILE NORTH OF SHASTA RIVER BRIDGE #02-0014 TO ROUTE 96 |
QA Service Level | 1 (Verified on 06/06/2017) |
Sample Information
Sample Taken Date | 01/08/2020 | Sample Unique Key | 21 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2020 |
Sample type | Acceptance | A brief description of the sample | Coarse Aggregate (3/8 inch x No. 8) |
The quantity of what the sample constitutes | 28 cy | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Shirley | Last name of sampler or witnessed by | McAllister |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D78321A | Linked DIME Sample ID | 2020-01-08-22 |
The fabricator/manufacturer/facility name | Mountain Ready Mix | Transportation Laboratory (TL) Number | 001679 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-47-0014::MOORES GRAVEL |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | CT759SP | Lot number | Unknown |
Sublot number | Unknown | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2020-01-08-21
DIME Test ID: 2020-01-08-21-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2020-02-04
Test Results
Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Karen Spliethof
Date of test: 01/10/2020
Top sediment column reading (single primary size): 0.2 in
Cleanness value (single primary size): 94
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/4/2020 ✔