Summary for Test 2020-01-27-21-4

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 214662
DEA: 081G4904
EFIS: 0816000002
DIST-CO-RTE-PM08-RIV-79-26.3/26.4
Award DateNot set
Closeout DateNot set
Work DescriptionCONSTR 2 SDWLKS,6 DRVWYS,CRB/GUTTER & OTHER ADA ITEMS
Location DescriptionIn Hemet between Menlo Ave. and Oakland Ave.
QA Service Level1 (Verified on 01/31/2020)

Sample Information

Sample Taken Date01/27/2020 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/28/2020
Sample typeVerification A brief description of the sample3/4 HMA-A-SP R15
The quantity of what the sample constitutesPSUE 4 Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byAll American Perris Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0118A-20 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAll American Asphalt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample3/4 HMA-A-SP R15 The fabricator/manufacturer designation for the sample105927
The plant numberUnknown A detailed description of where the material sample was collectedBelt Cut at All American Perris Plant
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2020-01-27-21
DIME Test ID: 2020-01-27-21-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-03-17

Test Results


Input Type: Measured
Tester's full name: Nader Rashidi
Date of test: 01/30/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 963 grams
Mass of the pycnometer with water (B): 654.3 grams
Mass of the oven dried sample (before pycnometer) (A): 490.5 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 486.8 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.564
Bulk specific gravity (SSD Basis): 2.614
Apparent specific gravity: 2.698
Absorption: 1.9 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/17/2020