Summary for Test 2020-01-06-23-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date01/06/2020 Sample Unique Key23
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/09/2020
Sample typeQuality Assurance A brief description of the sample#6 x 2'-10" diameter hoops
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-003-20 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)9000799
Hoop Manufacturer Lot Number(s)23 Material Standard CodeASTM A706
Material Grade60 Rebar Size6
Diameter of Hoop2'-10" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel CA
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2020-01-06-23
DIME Test ID: 2020-01-06-23-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2020-01-09

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 01/09/2020
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11236/19mm0.4445018.64102315Ok Neckingbewing

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 1/9/2020