Summary for Test 2019-12-11-1-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 214077 DEA: 101C5304 EFIS: 1015000002 |
---|---|
DIST-CO-RTE-PM | 10-STA,SJ-5,99-Var |
Award Date | 05/24/2019 |
Closeout Date | 04/26/2021 |
Work Description | OVERHEAD AND ROADSIDE SIGNS, AND MODIFY ELECTRICAL SYSTEMS. |
Location Description | SAN JOAQUIN AND STANISLAUS COUNTIES AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 04/11/2019) |
Sample Information
Sample Taken Date | 12/11/2019 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/18/2019 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A325 1/2 x 2 3/4 |
The quantity of what the sample constitutes | 68 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jane | Last name of sampler or witnessed by | Lillard |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 916-308-9430 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Structural and Steel Products | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S52-032-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | NF15203266 | Nut Mfg. Lot Number(s) | |
Washer Mfg. Lot Number(s) | Bolt Specification | A325 | |
Bolt Length(s) | 2 3/4" | Nut Specification | n/a |
Washer Specification | n/a | Finish | mechanically galvanized to ASTM B695-04, class 55, type I |
Diameter/Size | 1/2" | Bolt Mfg. Lot Number | 365604A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-12-11-1
DIME Test ID: 2019-12-11-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-12-24
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 12/20/2019
UTM: 450kip
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1A | 365604A | 0.5000 | 20406 | 90.77 | 10.00 | A325 Wedge Tensile | spaine |
General comments (publicly viewable) (Max 1000 characters): A325 Wedge Tensile
Test Graph
Source: Bluehill Data Point FileTest was verified on 12/24/2019 ✔