Summary for Test 2019-11-26-8-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 213746 DEA: 080Q75U4 EFIS: 0817000114 |
---|---|
DIST-CO-RTE-PM | 08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2 |
Award Date | 04/18/2019 |
Closeout Date | 06/28/2022 |
Work Description | REPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/17/2019) |
Sample Information
Sample Taken Date | 11/26/2019 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/26/2019 |
Sample type | Department Acceptance | A brief description of the sample | 3/8" HMA-A R15 PG64-28M(0.5% LAS) |
The quantity of what the sample constitutes | 2 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0706A-19 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan-Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/8 inch | Lot number | Unknown |
Sublot number | Unknown | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2019-11-26-8
DIME Test ID: 2019-11-26-8-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2019-12-05
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Anthony Diaz
Date of test: 12/02/2019
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: no data
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): no data
Moisture Content: no data
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.30 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/5/2019 ✔