Summary for Test 2019-10-25-21-4

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/25/2019 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/01/2019
Sample typeVerification A brief description of the sample3/4" Combined Aggregate
The quantity of what the sample constitutesJMF Prequalification From where was the sample collectedManufacturer
First name of sampler or witnessed byCody Last name of sampler or witnessed byBrown
Title of sampler Telephone number of sampler
Laboratory sample identification19-263 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Indunsties Lake Herman Batch Transportation Laboratory (TL) Number911405
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002::LAKE HERMAN QUARRY
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedBatch Plant Hot Bins
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-10-25-21
DIME Test ID: 2019-10-25-21-4
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2019-12-04

Test Results


How many times will the test be run?: 3 Times
Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 12/04/2019
Sand Equivalent (Test 1): 74
Sand Equivalent (Test 2): 84
Sand Equivalent (Test 3): 72
Sand Equivalent: 77
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/4/2019