Summary for Test 2019-11-13-34-8
Test performed: ASME B1.2-83r01Project Information
Project Identifiers | Project ID: 214399 DEA: 044Q3404 EFIS: 0419000383 |
---|---|
DIST-CO-RTE-PM | 04-MRN-580-1.3, 1.30 |
Award Date | 05/23/2019 |
Closeout Date | 03/16/2021 |
Work Description | Near San Quentin, in the Richmond-San Rafael Bridge, heat straightening truss chords |
Location Description | Near San Quentin, in the Richmond-San Rafael Bridge |
QA Service Level | 1 (Verified on 09/06/2019) |
Sample Information
Sample Taken Date | 11/13/2019 | Sample Unique Key | 34 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2019 |
Sample type | Quality Assurance | A brief description of the sample | fastener Assemblys |
The quantity of what the sample constitutes | 157 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Bay Bolt | Transportation Laboratory (TL) Number | C835659 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-113-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 6693-01 thru 6693-05 |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | 413071C, 411686D, 410347D | |
Washer Mfg. Lot Number(s) | 0818-925, 141843 | Bolt Specification | A325 |
Bolt Length(s) | 1.75, 2, 2.25, 2.5, 3, 4.25 | Nut Specification | A563 |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | .75", 1" | Bolt Mfg. Lot Number | 396988B, 797064, 818657, 752434, 816309, 3865 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2019-11-13-34
DIME Test ID: 2019-11-13-34-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASME B1.2-83r01: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)
Test Release Date: 2019-11-20
Test Results
Input Type: Calculated
Tester's full name: Steven Paine
Date of test: 11/20/2019
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 396988B
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 N USA
Size: .75 in
Bolt Length: 1.75 in
Gage Type: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/20/2019 ✔