Summary for Test 2019-11-15-18-5

Test performed: ASTM D4791-10

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date11/15/2019 Sample Unique Key18
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/15/2019
Sample typeVerification A brief description of the sampleVirgin 1/2-inch Type A Aggregate
The quantity of what the sample constitutesJMF Verification From where was the sample collectedSource
First name of sampler or witnessed byAdam Last name of sampler or witnessed byZeither
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010::CALMAT/PLEASANTON
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedHot Drop
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size1/2 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown Aggregate Mix NumberNot set

Test Details

DIME Sample ID: 2019-11-15-18
DIME Test ID: 2019-11-15-18-5
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: ASTM D4791-10: Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate (Withdrawn 2019) (Flat and Elongated Particles)
Test Release Date: 2019-11-17

Test Results


Method A - Percentage of Flat Particles, Elongated Particles, and Flat & Elongated Particles
Method B - Flat & Elongated Particles

Method: A
Determination: By Mass
Dimensional ratio used: 1:5
Input Type: Calculated
Tester's full name: Clinton Edmiston
Date of test: 11/15/2019
Weighted percentage of particles (by mass) that were flat: 0 %
Weighted percentage of particles (by mass) that were elongated: 0 %
Weighted percentage of particles (by mass) that were both flat and elongated: 0 %
Weighted percentage of particles (by mass) that were neither flat nor elongated: 0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/17/2019