Summary for Test 2019-11-15-7-9
Test performed: CTM 227-December 2014Project Information
Project Identifiers | DEA: No Project |
---|---|
DIST-CO-RTE-PM | --- |
Award Date | Not set |
Closeout Date | 11/01/2022 |
Work Description | Special project identifier for material not associated with a project |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 11/15/2019 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2019 |
Sample type | Quality Control | A brief description of the sample | Combined 1/2" Type A (Virgin Aggregate) |
The quantity of what the sample constitutes | JMF Submittal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Sampler First Name | Last name of sampler or witnessed by | Sampler Last Name |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010::CALMAT/PLEASANTON |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Untreated Stockpile | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2019-11-15-7
DIME Test ID: 2019-11-15-7-9
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2019-11-17
Test Results
Describe the gradation of the aggregate or the test method:: According to ASTM C 117 v04
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 11/15/2019
The method used?: Procedure A
Mass of sample before washing: 100 grams
Mass of sample after washing: 25 grams
Percent finer than No. 200 sieve: 75.0 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/17/2019 ✔