Summary for Test 2019-10-31-1-2

Test performed: ASTM F606-14

Project Information

Project IdentifiersProject ID: 212687
DEA: 06442544
EFIS: 0612000175
DIST-CO-RTE-PM06-KER-46,5-31.5-33.2
Award Date01/11/2018
Closeout Date11/19/2021
Work DescriptionCONVERT 2-LANE TO 4-LANE CONVENTIONAL HIGHWAY.
Location DescriptionKERN COUNTY NEAR LOST HILLS FROM 1.0 MILE EAST OF LOST HILLS ROAD TO 0.7 MILE EAST OF ROUTE 46/5 SEPARATION
QA Service Level1 (Verified on 03/12/2018)

Sample Information

Sample Taken Date10/31/2019 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/08/2019
Sample typeQuality Assurance A brief description of the sample3/4"-10 x 29" ATR F1554-55 Plain
The quantity of what the sample constitutes16 From where was the sample collectedDistributor
First name of sampler or witnessed byBrian Last name of sampler or witnessed byMurray
Title of samplerQA Telephone number of sampler213 435 4055
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameIndustrial Bolt and Supply Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL140-047-19 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)58038747 Nut Mfg. Lot Number(s)422614A
Washer Mfg. Lot Number(s)218L036-132 Bolt SpecificationASTM F1554-55
Bolt Length(s)29" Nut SpecificationASTM 563 DH
Washer SpecificationASTM F436-11 FinishPlain
Diameter/Size3/4" Bolt Mfg. Lot Number02
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-10-31-1
DIME Test ID: 2019-10-31-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2019-11-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 11/12/2019
UTM: 400kip
Temperature: 72
NumSampleSizeArea (in^2)Peak Load (lbf)Peak Load (kN)Tensile Strength (psi)Stress at Offset (psi)Load at Offset (lbf)Comments
11AUNC 3/4 0.33430221134904826785322663F1554 Tensile

General comments (publicly viewable) (Max 1000 characters): F1554 Tensile
Test Graph
Source: Bluehill Data Point File