Summary for Test 2019-10-28-5-1
Test performed: ASTM A615-15Project Information
Project Identifiers | Project ID: 212036 DEA: 044K2404 EFIS: 0417000284 |
---|---|
DIST-CO-RTE-PM | 04-MRN,MRN-1-10.9, 10.8/10.9, 10.90, 6.6/10.9 |
Award Date | 01/31/2017 |
Closeout Date | 10/17/2022 |
Work Description | Construct Solier Pile Wall |
Location Description | Not set |
QA Service Level | 1 (Verified on 03/17/2017) |
Sample Information
Sample Taken Date | 10/28/2019 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2019 |
Sample type | Quality Assurance | A brief description of the sample | B7X Couplers for 32mm |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Willaims Form Engineering | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-044-19 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A513 | Threaded Bar Grade | 513 |
Threaded Bar Type | Rebar Size | ||
Nut Specification for Threaded Bar | ASTM A108 | System Manufacturer | Willaims Form Engineering |
Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
Coating Standards | ASTM A123 galvanized | Bar Heat Number(s) | 4173505 and 4124818 |
Nut Heat Number(s) | 8295752 | Bar Lot Number | C21032757 and C21032856 |
Nut Lot Number | Unknown | Coupler Heat Number(s) | M54421 |
Coupler Grade | 90 |
Test Details
DIME Sample ID: 2019-10-28-5
DIME Test ID: 2019-10-28-5-1
Testing Lab: CT HQ - Sacramento Materials Management Branch Field Office
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2019-11-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: She Vang
Date of test: 11/06/2019
UTM: 400KIP
Temperature: 72 f
Num | Sample | Size | Mfg Lot | Area (sqin) | Tensile Strength (psi) | Stress at Offset (psi) | Total Elongation (%) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 1 | 10/32mm | 4124818 | 0.556 | 91326 | 82822 | 0 | A513 Bar, Nut Heat 8295752 coupler, bar broke | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/6/2019 ✔