Summary for Test 2019-10-16-6-6

Test performed: ASTM F606-14a

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date10/16/2019 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2019
Sample typeAcceptance A brief description of the sampleA490 Bolts
The quantity of what the sample constitutes6 From where was the sample collectedJob Site
First name of sampler or witnessed byMichael Last name of sampler or witnessed byEmami
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameLeJeune Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)75073905 6214661005 140647 75067668 10508080 6214506106 262342 75070176 6214552009 277861 Nut Mfg. Lot Number(s)30581-6214661005 28846-6214661005 27185-6214506106 27807-6214552009
Washer Mfg. Lot Number(s)0115-716 D3644 114 D4851 Bolt SpecificationA490
Bolt Length(s)6" 7" 10" Nut SpecificationA563 DH
Washer SpecificationF436 FinishGeomet
Diameter/Size1.25" Bolt Mfg. Lot Number050919-4FM 041719-1CM 051519-7EM 27128-105
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2019-10-16-6
DIME Test ID: 2019-10-16-6-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2019-10-29

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 10/23/2019
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
15A050218-1CG-601.2500160995716.146.00A490 Wedge Tensilespaine

General comments (publicly viewable) (Max 1000 characters): A490 Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 10/29/2019