Summary for Test 2019-10-14-3-9
Test performed: ASTM C430-8Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/14/2019 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/14/2019 |
Sample type | Annual Source Testing | A brief description of the sample | Type IL Cement |
The quantity of what the sample constitutes | 1 Bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM193901 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | LaFarge | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | LaFarge |
---|---|---|---|
Mill | Exshaw Type IL | Type of Cementitious Material | Blended Cement |
Test Details
DIME Sample ID: 2019-10-14-3
DIME Test ID: 2019-10-14-3-9
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C430-8: Standard Test Method for Fineness of Hydraulic Cement by the 45-μm (No. 325) Sieve
Test Release Date: 2021-01-08
Test Results
Type of Material: Hydraulic Cement
Input Type: Measured
Tester's full name: Stephen Donnelly
Date of test: 10/17/2019
Residue from the sample retained on the No. 325 sieve (Rs): 0.0089 grams
Sieve correction factor (C): 83.72
Corrected residue, % (Rc): 1.6 %
Fineness of the cement as the corrected percentage passing the 45 micrometers sieve (No. 325): 98.4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/8/2021 ✔