Summary for Test 2014-08-04-8646-4
Test performed: CTM 301-March 2000Project Information
Project Identifiers | Project ID: 3951 DEA: 07202114 EFIS: 0700020869 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-17.2/26.4 |
Award Date | 04/04/2012 |
Closeout Date | 06/16/2021 |
Work Description | PAVE ROADWAY WITH LONG LIFE PAVEMENT AND WIDEN ROADWAY AND BRIDGES |
Location Description | LOS ANGELES COUNTY ON ROUTE 710 AT VARIOUS LOCATIONS FROM LOS ANGELES RIVER BRIDGE TO RAMONA BOULEVARD UNDERCROSSING |
QA Service Level | 1 (Verified on 11/27/2012) |
Sample Information
Sample Taken Date | 08/04/2014 | Sample Unique Key | 8646 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/06/2014 |
Sample type | Acceptance | A brief description of the sample | Class 3 Aggregate Base |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Other |
First name of sampler or witnessed by | Christian | Last name of sampler or witnessed by | Cruz |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | 4214B | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Sta 1138 25 | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Atlantic Blvd contractors yard |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Sta 1138 25 | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | ||
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-08-04-8646
DIME Test ID: 2014-08-04-8646-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2014-09-16
Test Results
How will the R value be determined?: By expansion pressure
Input Type: Calculated
Tester's full name: Danilo Ferrer
Date of test: 08/15/2014
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 96 %
As Received Gradation, Percent Passing 1/2 in. sieve: 81 %
As Received Gradation, Percent Passing 3/8 in. sieve: 72 %
As Received Gradation, Percent Passing #4 sieve: 55 %
As Received Gradation, Percent Passing #8 sieve: 41 %
As Received Gradation, Percent Passing #16 sieve: 33 %
As Received Gradation, Percent Passing #30 sieve: 25 %
As Received Gradation, Percent Passing #50 sieve: 19 %
As Received Gradation, Percent Passing #100 sieve: 13 %
As Received Gradation, Percent Passing #200 sieve: 9.9 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 84 %
As Used Gradation, Percent Passing 3/8 in. sieve: 75 %
As Used Gradation, Percent Passing #4 sieve: 57 %
As Used Gradation, Percent Passing #8 sieve: 43 %
As Used Gradation, Percent Passing #16 sieve: 34 %
As Used Gradation, Percent Passing #30 sieve: 26 %
As Used Gradation, Percent Passing #50 sieve: 19 %
As Used Gradation, Percent Passing #100 sieve: 14 %
As Used Gradation, Percent Passing #200 sieve: 10.3 %
R value: 75
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/16/2014 ✔